Model: GMEV40CMC1B-WC
- Power: 9.6 kW AC Level 2 charger, 240 Vac, 40 A
- Connectivity: 4G (cellular), Ethernet
Cellular Setup (Non-Eaton SIM):
-
Replace the SIM Card:
- Carefully open the EV charge station to access the internal components.
- Replace the Eaton-provided SIM card with your own SIM card, ensuring it is compatible with Verizon, AT&T, or T-Mobile networks.
-
APN Configuration:
- Download and install the Eaton EV Charger Commissioning Tool here on a Windows 8/10/11 PC. The Software can be found in Resources under Software, firmware, and applications.
- In the Commissioning Tool, go to Settings -> Cellular.
- Enter the APN (Access Point Name) provided by your SIM card provider.
- Click Submit to save the APN settings.
-
Reboot and Verify:
- Reboot the charge station via Other Functions -> Reboot EV Charge Station.
- Disconnect the Ethernet cable if it is connected.
-
On the LCD screen:
- A 4G will appear, indicating the station is connected to the 4G network.
- The Eaton CNM chain icon will illuminate once the station successfully connects to the Eaton CNM.
Ethernet Setup:
-
Connect Ethernet Cable:
- Plug in the Ethernet cable directly from a router or network switch into the charge station’s Ethernet port.
-
Verify Ethernet Connection:
-
On the LCD screen:
- A computer screen with a checkmark icon will appear when the station is connected via Ethernet.
- The Eaton CNM chain icon will be illuminated to show connection to the Eaton CNM.
-
On the LCD screen: